header valves
Valves & Actuation

Series 19 Failsafe

Series 19 CAV & SAV Failsafe Electric Actuators

A failsafe actuator cycles as on/off while charging internal capacitors. When power is lost, the capacitors discharge and power the unit to a predetermined fail position. When power is restored, the capacitors charge up again.

Series 19 SAV Failsafe

series-19-sav-actuator

Applications:

Remote locations, locations with no air supply, colder temperatures, smaller valves, low cost applications

Sizes:

S20FS, S50FS, S110FS

Amp Draw:

0.18 Amp for S20, 0.24 Amp for S50, 0.84 for S110                

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs to 973 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color-coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz

24 AC/DC

Max Temp:

150° F


Series 19 CAV Failsafe Actuator

cav-blue

Applications:

Remote locations, locations with no air supply, colder temperatures, smaller valves, low cost applications

Size:

C20 for 3/8" - 2" Omni Type-27 Ball Valves

Amp Draw:

0.18 Amp

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz

24 AC/DC

Max Temp:

150° F